Sample approval & materials · 7 MIN READ
How to Check a Squishy Sample for Your Shop
Use this checklist to inspect a physical TPR squishy sample and record what you actually observe. Keep the SKU, outer material, filling and package reference together. The separate sample-to-bulk guide handles approval owners, revisions and production changes.
Identify the sample, compare its supplier specification, measure it using an agreed method, inspect its surface and seams, and record ordinary handling and packaging observations. Download the inspection worksheet below. The filled example uses a fictional item to teach the recording method; it is not a CurioSpan test result or a safety assessment.
Set up the sample record
Give each received sample a reference, SKU, variant and revision. Photograph the front, back, side and packaging beside that reference. Record the specification or quote version, who checked the sample and when, plus whether it was just unpacked or had been handled. Use a separate row for each check.
Download the sample inspection CSV
The file contains clearly marked fictional teaching rows and blank buyer rows. Replace the teaching rows with your own SKU and observations. A blank tolerance, measurement or document field means it remains open; it does not mean zero, not applicable or approved.
Keep outer material and filling separate
The published CS-CR-39 Crown Chicken record lists TPR outer material and brick clay filling. CS-VAS-02 Vaseline Cheese Cube lists a TPR outer and Vaseline filling. Record the supplier’s composition statement separately from your handling observations: appearance or feel alone cannot verify composition.
Keep Crunchy / Brick Clay distinct from a coating
CurioSpan’s listed Crunchy / Brick Clay examples use a TPR outer and brick clay filling. Do not replace that construction with “wax crispy” because of a product name or image. Ask for the exact coating description when it is relevant to the selected SKU.
Use a separate reference for solid PU
CS-PU-02 Crispy-coated Butter Bar is listed as solid PU slow-rising foam with no separate filling, 15 × 6.5 × 5 cm, 107 g and 144 pcs/carton; its coating detail needs SKU confirmation. These fields do not describe a TPR sample. Use the material guide for the broader construction comparison.
Record physical checks with a repeatable method
Agree the method and any acceptance criteria with the buyer and supplier before treating a result as accepted. This checklist sets no universal recovery time, odor limit, tolerance or durability threshold. Record observations on the sample you received; do not generalize them to every unit in a future order.
| Check | How to record it | Keep with the result |
|---|---|---|
| Identity and variant | Compare the sample, label and package with the selected SKU and approved image. | Sample reference, variant and specification revision |
| Dimensions and weight | Record each measured axis and its unit, the item orientation and whether packaging is included. Record the scale reading separately. | Method, measured values and agreed tolerance; leave missing values open |
| Surface, seams and openings | Look around the sample under consistent lighting; note visible marks, finish differences, seams or openings that need review. | A dated photo reference and a precise location rather than “poor quality” |
| Ordinary handling | Use the agreed handling method and record what was done, the response observed and any change afterward. | Handling conditions and observations; no assumed sound or recovery promise |
| Retail packaging | Check the actual package, label revision, fit and included pieces against the brief. | Package revision, photos and any unresolved quantity or measurement |
Read a fictional filled example
| Field or check | Example entry | Review action |
|---|---|---|
| Reference | DEMO-TPR-01 · sample R1 · brief DEMO-BRIEF-B | Keep all observations under this one fictional revision |
| Width | Requested width: 50 mm; recorded width: 49 mm; allowable variation: not yet agreed | Hold the decision until the method and tolerance are agreed; do not label this pass or fail |
| Handling observation | No handling check recorded | Leave the result NOT CHECKED; do not infer recovery or durability |
| Package artwork | Brief requests artwork B; sample package is marked A | Request the intended artwork and review the next package revision |
| Overall outcome | REVISE / OPEN — width criterion and artwork unresolved | The teaching record does not authorize production |
Review packaging and document scope separately
Confirm display-box quantity, inner pack, carton quantity, carton dimensions and gross weight for the approved packaging. Product measurements do not establish the packed dimensions. CS-CR-39 has a 12-pieces-per-style request point and a listed 192 pcs/carton pack; final production MOQ and pack-out remain SKU-specific.
CurioSpan currently has supporting test reports for eligible Crunchy / Brick Clay SKUs; See the Compliance Guide for destination-specific documentation. Request the exact covered SKU and report scope. A supporting test report and a CPC are different documents. Use the test-report and CPC guide and review the destination requirements with the responsible buyer or importer. Physical sample inspection does not confirm market compliance.
Hand observations to the approval owner
Save the inspection sheet and photo references without overwriting an earlier sample. Send each open item with the SKU, revision and requested action. The sample-to-bulk approval guide provides the separate record for the decision owner, approval scope and changes before production.
Carry the agreed material, filling, size, weight, package, labels and document status into the written quote. A new color, filling, coating or package version needs an explicit review decision, rather than a silent update to the previous sample record.
Is TPR the same thing as the filling?
No. TPR describes the outer material on the listed Crunchy and Vaseline examples. The filling is a separate construction field, such as brick clay or Vaseline.
Does the fictional example describe a CurioSpan product?
No. DEMO-TPR-01, its measurements and observations are invented only to teach the worksheet. They are not a real product inspection or a customer record.
What if no tolerance has been agreed?
Record the measurement and method, keep the decision open, and ask the buyer and supplier to agree the applicable criterion. A missing tolerance is not an automatic pass or fail.
Does sample approval replace destination compliance review?
No. Sample approval confirms the commercial product specification for the stated scope. The buyer must separately review destination requirements, labels, age grading and the available documents for the exact SKU.
